Reference-based product illustration. The shown size and connections are one catalogue configuration.

Safety & protectionARD-SF-006

Connection options

Cryogenic safety valve

Female BSP/NPT

A spring-loaded safety-valve catalogue reference offering female BSP or NPT connections. DN15–25 are listed, with a separate reference arrangement for connection and spring-band reference.

Size
DN 15–25
Body material
CF8
Connections
Female BSP / NPT threaded
Operation
Spring-loaded pressure relief
Pressure
Set pressure to specify
Temperature
−196 to +80°C · series*

Relief settings and nominal ratings are specified separately. Confirm the selected configuration.

Engineered for your application

A spring-loaded safety-valve catalogue reference offering female BSP or NPT connections. DN15–25 are listed, with a separate reference arrangement for connection and spring-band reference.

Sizes and pressure ratings depend on construction, materials and configuration. Confirm the selected pressure-temperature rating with the quotation.

Technical data

The specification, in detail.

ARD-SF-006 technical data
ParameterTechnical specification
Size rangeDN 15–25
Pressure ratingsSet pressure to specify
ConnectionFemale threaded, BSP / NPT
Pressure / settingSpecify rating and required set pressure
OperationSpring-loaded pressure relief
series temperature*-196°C to +80°C
MediumLNG, LOX, LN2, LAr, CO2

Nominal pressure and ASME class are different rating systems. Confirm the pressure–temperature rating for the selected material and design.

End connections

Define the interface.

BSP threadedNPT threaded

Shown configuration: The supplied illustration shows a female side port and a male downward adapter. Confirm the complete inlet/outlet arrangement for the female-threaded catalogue option.

ARD-SF-006 end connection details
Connection detailConnection / selection requirement
Published connectionBSP · NPT · Female
Thread standardBSP and NPT are separate options. Confirm exact designation, taper/parallel form and male/female inlet and outlet; metric reference threads must not be relabelled as BSP or NPT.
Reference drawing scopeSupplied female-threaded relief arrangement, DN15 and DN25. M1/M2 are the exact reference connection designations, including metric threads; do not substitute BSP/NPT. DN20 is not tabulated. Set-pressure bands do not establish relief capacity.
Pictured thread arrangementThe supplied illustration shows a female side port and a male downward adapter. Confirm the complete inlet/outlet arrangement for the female-threaded catalogue option.

The illustration shows one configuration. Published connection alternatives are options for enquiry; their availability depends on size, rating, material and design. Installation dimensions come from the drawing, not the illustration.

Materials

From body to seal.

ARD-SF-006 material schedule
ComponentMaterial / option
BodyCF8
SeatHPb59-1
DiscHPb59-1

Supplied reference arrangement

Materials apply to the supplied reference arrangement. Supplied female-threaded relief arrangement, DN15 and DN25. M1/M2 are the exact reference connection designations, including metric threads; do not substitute BSP/NPT. DN20 is not tabulated. Set-pressure bands do not establish relief capacity.

ARD-SF-006 reference arrangement materials
ComponentReference arrangement material
CoverHPb59-1
Spring SeatS30408
Adjusting RingHPb59-1
Adjusting ScrewHPb59-1
Ejector Bar20Cr13
BodyS30408
Lock NutS30408
SpringS30210
SealingT2
SealingPTFE
DiscS32168
Valve SeatS32168
BonnetS30408

Published material alternatives are configuration-dependent. H.F. denotes hard facing; the exact grade and material certificates are confirmed with the offer.

Selection notes

Defined around your application.

  • Catalogue body: CF8
  • Published connections: BSP · NPT · Female
ARD-SF-006 engineering requirements
Engineering dataConfiguration requirement
Dimension dataReference table and drawing: DN15, DN25. Dimensions and connection reference.
Installation drawingConfirm BSP or NPT, male/female ends, thread sizes, engagement, end-to-end length and installation clearance.
Pressure-temperature ratingConfirm allowable inlet pressure at the relieving temperature for the selected body, trim and seals. Specify set pressure, back pressure and certified relief capacity separately.

Sizes and pressure ratings depend on construction, materials and configuration. Confirm the selected pressure-temperature rating with the quotation.

*−196 to +80°C is the series/reference range. It does not establish the allowable pressure at each temperature or suitability of every seat, seal and actuator. Confirm the selected assembly’s minimum design temperature and pressure–temperature curve.

Specify required set pressure, relieving medium and temperature, back pressure and certified capacity. Spring-setting bands, nominal pressure and flange rating are separate values. No capacity or approval is inferred from the product illustration.

the technical record offers female BSP/NPT connections, while its illustration includes a male downward adapter. Confirm the complete port arrangement using the order drawing; the image is retained as a illustrated arrangement.

Catalogue construction and supplied reference-arrangement materials are shown separately below the material schedule. Use the approved drawing for the quoted body, trim and connections.

Published ratings do not establish suitability for every listed medium. Oxygen cleaning, material compatibility, trapped-liquid relief and project approvals are specified for the selected assembly. Liquid-hydrogen and helium service require a separate temperature and material review.

Arden product datasheet

Product code ARD-SF-006 · Revision 2026-10-28. Product illustrations show one configuration; the approved order documentation defines the supplied assembly.

Download PDF

Dimensions

Plan the connection.

Dimensions apply to the tabulated version only. Confirm the approved outline drawing for the selected size, rating and connections before installation.

Supplied female-threaded relief arrangement, DN15 and DN25. M1/M2 are the exact reference connection designations, including metric threads; do not substitute BSP/NPT. DN20 is not tabulated. Set-pressure bands do not establish relief capacity.

Dimensions and connection reference

ARD-SF-006 dimensions
DNHH1M1M2LOperating pressure (MPa)Set pressure (MPa)
1515056G3/4M30x1.5354.00.4 - 1.0
1515056G3/4M30x1.5354.01.0 - 2.0
1515056G3/4M30x1.5354.02.0 - 3.0
2519769G1 1/4M36x2474.00.4 - 1.0
2519769G1 1/4M36x2474.01.0 - 2.0
2519769G1 1/4M36x2474.02.0 - 3.0

Linear dimensions are in mm and weights in kg unless stated otherwise. Pressure bands in MPa, thread designations and ISO mounting codes are not linear dimensions. Thread designations follow the reference. An em dash means no value is published. Confirm a certified outline drawing for the selected configuration.

Documentation

Product documents

Download the Arden data sheet for ARD-SF-006, or request the outline drawing for your selected configuration.

Product code ARD-SF-006 · Revision 2026-10-28. Illustrations show one configuration; approved order documentation defines the supplied assembly.

ARD-SF-006

Cryogenic safety valve · female BSP/NPT

Cryogenic safety valve · female BSP/NPT — reference-based product illustration, Female BSP / NPT threaded

Reference-based product illustration. The shown size and connections are one catalogue configuration.

Find your next solution

Search Arden

Privacy

Your enquiry. Your details.

Arden Cryogenics is based in Pietarsaari, Finland.

When you make an enquiry

When you submit the form, your name, company, work email, selected product and application details are sent securely to our sales team at sales@ardencryogenics.com. Our hosting and email delivery providers process these details to deliver your enquiry.

Arden Cryogenics uses the information you provide to respond, prepare a quotation and manage the related business correspondence. Submitting an enquiry does not subscribe you to marketing emails.

Cookies and site operation

This site does not set advertising or analytics cookies. The hosting provider may process technical request data to deliver and protect the site.

Contact

For questions about your information, contact sales@ardencryogenics.com.