Test & pilot rigs
Local isolation, pneumatic control and electrically operated valves for the selected sequence.
Research & Technology
From a laboratory cold line to a pilot installation, make the test conditions and interfaces part of the valve selection.
12 product references · Specifications & datasheets

The application
Research installations often combine tight space constraints, repeated cool-down cycles and specific flow or leakage requirements. A clear valve schedule helps separate isolation, control and measurement duties. The selection below focuses on products with published liquid-nitrogen service.
Local isolation, pneumatic control and electrically operated valves for the selected sequence.
Vacuum-jacketed globe, shut-off and lift-check configurations for LN2 pipework.
Liquid-level manifolds, compact globe valves and strainers for instrument and process lines.
Selection essentials
Products for this application
A focused selection with liquid nitrogen explicitly listed. Use dedicated LH2 products for hydrogen duties and request a separate review for helium cold-end service.

ARD-VJ-002
A jacketed emergency shut-off configuration combining cryogenic insulation with pneumatic operation.

ARD-CV-001
A diaphragm-actuated globe valve with an extended stem for cryogenic process control.

ARD-CV-002
An electrically operated cryogenic globe valve with flanged connections and published coil-voltage options.

ARD-VJ-001
A vacuum-jacketed globe configuration for insulated cryogenic pipework.

ARD-GL-006
A compact PN320 globe-valve reference for socket-weld cryogenic lines. The catalogue lists DN10–25 with a CF8 body; the supplied arrangement drawing covers a different body material.

ARD-IN-001
A compact valve manifold for liquid-level indication connections on cryogenic equipment.
Enquiry range — technical confirmation required

ARD-CK-002
A bolted-cap non-return range covering small process lines through DN 200.

ARD-GL-008
A right-angle globe valve with a long stem and CF8 body. The catalogue lists DN32, DN40 and DN50 socket-weld options for cryogenic pipe layouts.

ARD-ST-001
A socket-weld cryogenic strainer with a CF8 body and S30408 filter element. Select the mesh or aperture, allowable pressure loss and maintenance clearance for the line.

ARD-GL-009
A CF8 long-stem globe valve for DN10–50 socket-weld installations. Published reference tables distinguish alternative socket bores for the selected pipe.

ARD-BV-008
A long-stem CF8 ball-valve range with socket-weld ends for DN10–50. Match the socket bore and depth to the selected pipe and actuator package.

ARD-VJ-003
An insulated lift-check configuration for DN25-50 cryogenic pipework, combining a vacuum-jacketed body arrangement with automatic non-return operation and PTFE sealing.
Adjust the category or technical filters, or tell us what you need.
Product ranges are offered as references for enquiry. Final size, materials, pressure–temperature limits and certification are confirmed for each selected assembly.
Need another configuration? Talk to our teamResearch & Technology
Send the medium, operating conditions and required valve duties. Your application will be included in the enquiry.