Illustrative assembly. Final construction, operator and connection details are confirmed for the selected configuration.

Emergency shut-offARD-ES-006

Butt weld (BW) connection

LH2 thermal-barrier pneumatic shut-off valve

Butt weld (BW)

A pneumatic LH2 shut-off globe assembly with an extended thermal-barrier bonnet. The cold pressure body and warm operating package are selected together for the required isolation sequence.

Size and pressure options require technical confirmation.

Size
DN 15-250 / NPS 1/2-10 - series scope
Body material
304L / 316L stainless steel
Connections
Butt weld (BW)
Operation
Pneumatic diaphragm
Pressure
ASME Class 150-300
Temperature
-253 to +80°C - LH2 selection

Configuration and operating limits are confirmed for your project.

Engineered for your application

A pneumatic LH2 shut-off globe assembly with an extended thermal-barrier bonnet. The cold pressure body and warm operating package are selected together for the required isolation sequence.

Series data guide enquiry and are not verified availability or approved operating limits for every size, pressure and execution. Confirm the selected LH2 configuration and pressure-temperature rating.

Explore the related valve family

Technical data

The specification, in detail.

ARD-ES-006 technical data
ParameterTechnical specification
Size rangeDN 15-250 / NPS 1/2-10 - series scope
Pressure ratingsASME Class 150-300
ConstructionPneumatic shut-off globe; thermal barrier; extended bellows/packing seal
OperationPneumatic diaphragm
MediumLH2 / liquid hydrogen
Insulation optionsVacuum jacket with multi-layer insulation or non-jacketed arrangement
Operating packageFail position, air pressure, solenoid, feedback and trip interface to specify
End standardButt weld to ASME B16.25

Nominal pressure and ASME class are different rating systems. Confirm the pressure–temperature rating for the selected material and design.

End connections

Define the interface.

Butt weld (BW)

Shown configuration: an inline globe body with two butt-weld stubs, long cold bonnet, pneumatic diaphragm actuator and side-mounted instrument assembly

ARD-ES-006 end connection details
Connection detailConnection / selection requirement
Process endsButt weld to ASME B16.25; confirm the selected pipe schedule.
Insulation interfaceDefine the jacket, vacuum boundary and extension length separately from the process connection.

The illustration shows one configuration. Published connection alternatives are options for enquiry; their availability depends on size, rating, material and design. Installation dimensions come from the drawing, not the illustration.

Materials

From body to seal.

ARD-ES-006 material schedule
ComponentMaterial / option
Body304L / 316L stainless steel
Trim / seatsSelected cryogenic metal and polymer trim; confirm grades for LH2

Published material alternatives are configuration-dependent. H.F. denotes hard facing; the exact grade and material certificates are confirmed with the offer.

Selection notes

Defined around your application.

  • Pneumatic remote isolation
  • Extended thermal-barrier bonnet
  • Cold-box maintenance planning
ARD-ES-006 engineering requirements
Engineering dataConfiguration requirement
Process dutySpecify LH2 phase, design temperature, pressure, flow and differential pressure.
Selected assemblyConfirm insulation interface, materials, leakage acceptance and project test documentation.

Series data guide enquiry and are not verified availability or approved operating limits for every size, pressure and execution. Confirm the selected LH2 configuration and pressure-temperature rating.

The size range is the combined LH2 family scope; confirm the emergency shut-off model matrix. A specified fail action, closing time or SIL status requires qualification of the complete assembly.

Published ratings do not establish suitability for every listed medium. Oxygen cleaning, material compatibility, trapped-liquid relief and project approvals are specified for the selected assembly. Liquid-hydrogen and helium service require a separate temperature and material review.

Arden product datasheet

Product code ARD-ES-006 · Revision 2026-10-29. Product illustrations show one configuration; the approved order documentation defines the supplied assembly.

Download PDF

Dimensions

Plan the connection.

Need installation dimensions?

No numeric dimension table is published for this reference. Request a configuration-specific outline drawing with your enquiry.

Request dimensions

Documentation

Product documents

Download the Arden data sheet for ARD-ES-006, or request the outline drawing for your selected configuration.

Product code ARD-ES-006 · Revision 2026-10-29. Illustrations show one configuration; approved order documentation defines the supplied assembly.

ARD-ES-006

LH2 thermal-barrier pneumatic shut-off valve

LH2 thermal-barrier pneumatic shut-off valve - illustrative assembly, an inline globe body with two butt-weld stubs, long cold bonnet, pneumatic diaphragm actuator and side-mounted instrument assembly

Illustrative assembly. Final construction, operator and connection details are confirmed for the selected configuration.

Find your next solution

Search Arden

Privacy

Your enquiry. Your details.

Arden Cryogenics is based in Pietarsaari, Finland.

When you make an enquiry

When you submit the form, your name, company, work email, selected product and application details are sent securely to our sales team at sales@ardencryogenics.com. Our hosting and email delivery providers process these details to deliver your enquiry.

Arden Cryogenics uses the information you provide to respond, prepare a quotation and manage the related business correspondence. Submitting an enquiry does not subscribe you to marketing emails.

Cookies and site operation

This site does not set advertising or analytics cookies. The hosting provider may process technical request data to deliver and protect the site.

Contact

For questions about your information, contact sales@ardencryogenics.com.