Illustrative assembly. Final construction, operator and connection details are confirmed for the selected configuration.

Check valvesARD-CK-011

Butt weld (BW) connection

LH2 extended-bonnet spring check valve

Butt weld (BW)

A self-acting spring-loaded non-return valve with an extended service bonnet for insulated LH2 pipework. The straight-through pressure body and removable upper closure support maintenance planning.

Size and pressure options require technical confirmation.

Size
DN 10-100
Body material
Stainless steel; selected grade to confirm
Connections
Butt weld (BW)
Operation
Automatic / spring-loaded
Pressure
PN40
Temperature
LH2 cold-service version at -253°C; upper limit +50°C

Configuration and operating limits are confirmed for your project.

Engineered for your application

A self-acting spring-loaded non-return valve with an extended service bonnet for insulated LH2 pipework. The straight-through pressure body and removable upper closure support maintenance planning.

Series data guide enquiry and are not verified availability or approved operating limits for every size, pressure and execution. Confirm the selected LH2 configuration and pressure-temperature rating.

Technical data

The specification, in detail.

ARD-CK-011 technical data
ParameterTechnical specification
Size rangeDN 10-100
Pressure ratingsPN40
ConstructionInline spring-loaded check with extended service bonnet
OperationAutomatic / spring-loaded
MediumLH2 / liquid hydrogen
Opening pressurePublished minimum opening pressure up to 0.3 bar; selected spring and flow response to confirm
InstallationHorizontal flow, service bonnet upwards
Vacuum interfaceOptional weld-in flange

Nominal pressure and ASME class are different rating systems. Confirm the pressure–temperature rating for the selected material and design.

End connections

Define the interface.

Butt weld (BW)

Shown configuration: two opposing butt-weld stubs, a straight pressure body and an extended upright service bonnet with bolted cap; no external operator

ARD-CK-011 end connection details
Connection detailConnection / selection requirement
Process endsSpecify pipe OD, wall thickness, material and weld preparation.
Insulation interfaceDefine the jacket, vacuum boundary and extension length separately from the process connection.

The illustration shows one configuration. Published connection alternatives are options for enquiry; their availability depends on size, rating, material and design. Installation dimensions come from the drawing, not the illustration.

Materials

From body to seal.

ARD-CK-011 material schedule
ComponentMaterial / option
BodyStainless steel; selected grade to confirm
Trim / seatsSelected cryogenic metal and polymer trim; confirm grades for LH2

Published material alternatives are configuration-dependent. H.F. denotes hard facing; the exact grade and material certificates are confirmed with the offer.

Selection notes

Defined around your application.

  • Self-acting non-return function
  • Extended maintenance bonnet
  • Optional vacuum-jacket interface
ARD-CK-011 engineering requirements
Engineering dataConfiguration requirement
Process dutySpecify LH2 phase, design temperature, pressure, flow and differential pressure.
Selected assemblyConfirm insulation interface, materials, leakage acceptance and project test documentation.

Series data guide enquiry and are not verified availability or approved operating limits for every size, pressure and execution. Confirm the selected LH2 configuration and pressure-temperature rating.

Specify the deeper cryogenic construction and seals for LH2. Confirm spring setting, pressure drop and reverse-flow closure against the actual operating cases.

Published ratings do not establish suitability for every listed medium. Oxygen cleaning, material compatibility, trapped-liquid relief and project approvals are specified for the selected assembly. Liquid-hydrogen and helium service require a separate temperature and material review.

Arden product datasheet

Product code ARD-CK-011 · Revision 2026-10-29. Product illustrations show one configuration; the approved order documentation defines the supplied assembly.

Download PDF

Dimensions

Plan the connection.

Need installation dimensions?

No numeric dimension table is published for this reference. Request a configuration-specific outline drawing with your enquiry.

Request dimensions

Documentation

Product documents

Download the Arden data sheet for ARD-CK-011, or request the outline drawing for your selected configuration.

Product code ARD-CK-011 · Revision 2026-10-29. Illustrations show one configuration; approved order documentation defines the supplied assembly.

ARD-CK-011

LH2 extended-bonnet spring check valve

LH2 extended-bonnet spring check valve - illustrative assembly, two opposing butt-weld stubs, a straight pressure body and an extended upright service bonnet with bolted cap; no external operator

Illustrative assembly. Final construction, operator and connection details are confirmed for the selected configuration.

Find your next solution

Search Arden

Privacy

Your enquiry. Your details.

Arden Cryogenics is based in Pietarsaari, Finland.

When you make an enquiry

When you submit the form, your name, company, work email, selected product and application details are sent securely to our sales team at sales@ardencryogenics.com. Our hosting and email delivery providers process these details to deliver your enquiry.

Arden Cryogenics uses the information you provide to respond, prepare a quotation and manage the related business correspondence. Submitting an enquiry does not subscribe you to marketing emails.

Cookies and site operation

This site does not set advertising or analytics cookies. The hosting provider may process technical request data to deliver and protect the site.

Contact

For questions about your information, contact sales@ardencryogenics.com.