Control valvesARD-CV-006
Butt weld (BW) connectionLH2 bellows-sealed angle control valve
Butt weld (BW)
An angle-pattern LH2 control assembly with bellows stem sealing, an extended cold section and a pneumatic diaphragm actuator with an electro-pneumatic positioner. Trim and actuator are selected from the required flow and pressure cases.
Size and pressure options require technical confirmation.
- Size
- DN 2-125; DN 150-300 on request
- Body material
- Stainless steel; selected grade to confirm
- Connections
- Butt weld (BW)
- Operation
- Pneumatic diaphragm with positioner
- Pressure
- PN10 / PN25 / PN40 - size dependent
- Temperature
- LH2 selection at -253°C; upper limit +50°C
Engineered for your application
An angle-pattern LH2 control assembly with bellows stem sealing, an extended cold section and a pneumatic diaphragm actuator with an electro-pneumatic positioner. Trim and actuator are selected from the required flow and pressure cases.
Series data guide enquiry and are not verified availability or approved operating limits for every size, pressure and execution. Confirm the selected LH2 configuration and pressure-temperature rating.
Explore the related valve familyApplications
Liquid HydrogenTechnical data
The specification, in detail.
| Parameter | Technical specification |
|---|---|
| Size range | DN 2-125; DN 150-300 on request |
| Pressure ratings | PN10 / PN25 / PN40 - size dependent |
| Construction | Angle-pattern globe control; bellows-sealed extended stem |
| Operation | Pneumatic diaphragm with positioner |
| Medium | LH2 / liquid hydrogen |
| Size / rating selection | PN40: DN2-80; PN25: DN2-100; PN10: DN125. Larger sizes require separate selection. |
| Control trim | Flow characteristic, Kv, rangeability and seat load selected for the duty |
| Air supply | Published actuator supply 6 to 6.5 bar; selected actuator requirements to confirm |
Nominal pressure and ASME class are different rating systems. Confirm the pressure–temperature rating for the selected material and design.
End connections
Define the interface.
Shown configuration: an angle body with two butt-weld stubs, extended cold section, round diaphragm actuator and side-mounted positioner
| Connection detail | Connection / selection requirement |
|---|---|
| Process ends | Specify pipe OD, wall thickness, material and weld preparation. |
| Insulation interface | Define the jacket, vacuum boundary and extension length separately from the process connection. |
The illustration shows one configuration. Published connection alternatives are options for enquiry; their availability depends on size, rating, material and design. Installation dimensions come from the drawing, not the illustration.
Materials
From body to seal.
| Component | Material / option |
|---|---|
| Body | Stainless steel; selected grade to confirm |
| Trim / seats | Selected cryogenic metal and polymer trim; confirm grades for LH2 |
Published material alternatives are configuration-dependent. H.F. denotes hard facing; the exact grade and material certificates are confirmed with the offer.
Selection notes
Defined around your application.
- Electro-pneumatic positioning
- Bellows stem seal and monitored warm seal
- Vacuum-jacket integration flange
| Engineering data | Configuration requirement |
|---|---|
| Process duty | Specify LH2 phase, design temperature, pressure, flow and differential pressure. |
| Selected assembly | Confirm insulation interface, materials, leakage acceptance and project test documentation. |
Series data guide enquiry and are not verified availability or approved operating limits for every size, pressure and execution. Confirm the selected LH2 configuration and pressure-temperature rating.
Normally-open or normally-closed arrangements are selected for the complete assembly; closing time and safety qualification are project-specific.
Published ratings do not establish suitability for every listed medium. Oxygen cleaning, material compatibility, trapped-liquid relief and project approvals are specified for the selected assembly. Liquid-hydrogen and helium service require a separate temperature and material review.
Arden product datasheet
Product code ARD-CV-006 · Revision 2026-10-29. Product illustrations show one configuration; the approved order documentation defines the supplied assembly.
Download PDFDimensions
Plan the connection.
Need installation dimensions?
No numeric dimension table is published for this reference. Request a configuration-specific outline drawing with your enquiry.
Request dimensionsDocumentation
Product documents
Download the Arden data sheet for ARD-CV-006, or request the outline drawing for your selected configuration.
Product code ARD-CV-006 · Revision 2026-10-29. Illustrations show one configuration; approved order documentation defines the supplied assembly.